Certification

Testing Certifications

To ensure the highest level of quality and safety, all BioCair products go through rigorous testing procedures
at fully accredited, third-party laboratories located in both Singapore and the United Kingdom.
Testings are conducted by leading certification bodies, including TUV SUD and SGS.

With test results assessed and approved by renowned testing laboratories,
BioCair ensures that the products we deliver are proven safe and tested to be effective for our consumers.

STUDY ITEMTESTING LABORATORYFINDINGSTEST REPORT REFERNCECONCLUSIONS
Killing Efficacy
SGS International
Able to kill 99.999% of E.coli, S.aureus, C.albicans, A.brasiliensis & P.aeruginosain in 30 secs and B.subtilis in 60 sec.08A1201470BioCair is fast & efective in eliminating pathogens, in compliance with US Pharmacopoeia Standard
HFMD Killing EfficacyAble to kill both Coxsackievirus A16 & Enterovirus 71 within 1 minuteEfficacy study of BioCair BC-65™ on HFMD virusesBioCair is proven to kill both HFMD viruses within 1 minute
Lead Mercury Arsenic Analysis
Less than 0.05ppm7191096284-CHM14-SSB-CR1No lead, mercury and arsenic found, BioCair is safe for use
Acute Oral Route Toxicity Analysis (GLP)
Category 5 or unclassified219192151-01-00-CR1BioCair does not cause ingestion toxicity
Acute Inhalation Toxicity Analysis (GLP)
No acute inhalation toxicity was observed2191004040-03-00-CR1BioCair does not cause inhalation toxicity
Ocular Irritation Analysis (GLP)
No eye irritation afer instillation2191004040-01-00BioCair does not cause eye irritation
Acute Dermal Irritation Analysis (GLP)
No skin irritation after instillation2191004040-02-00BioCair does not causeskin irritation
Air Sampling in a Confined RoomBefore BioCair® disinfection:TBC* 130cfu/m3 of airAfer disinfection:TBC <10cfu/m3 of airFB819719/ABioCair is proven to be fast & efective in killing airborne pathogens in the room
Killing Eficacy
Able to kill 99.999% ofE.coli, S.aureus, C.albicans,A.brasiliensis & P.aeruginosain 30 secs and B.subtilis in 60 sec.
08A1201470
BioCair is fast & efective in eliminating pathogens, in compliance with US Pharmacopoeia Standard
HFMD Killing Eficacy
Able to kill both Coxsackievirus A16 & Enterovirus 71 within 1 minute
Eficacy study of BioCair BC-65™ on HFMD viruses
BioCair is proven to kill both HFMD viruses within 1 minute
Lead Mercury Arsenic Analysis
Less than 0.05ppm
7191096284-CHM14-SSB-CR1
No lead, mercury and arsenic found, BioCair is safe for use
Acute Oral Route Toxicity Analysis (GLP)
Category 5 or unclassified
219192151-01-00-CR1
BioCair does not cause ingestion toxicity
Acute Inhalation Toxicity Analysis (GLP)
No acute inhalation toxicity was observed
2191004040-03-00-CR1
BioCair does not cause inhalation toxicity
Ocular Irritation Analysis (GLP)
No eye irritation afer instillation
2191004040-01-00
BioCair does not cause eye irritation
Acute Dermal Irritation Analysis (GLP)
No skin irritation after instillation
2191004040-02-00
BioCair does not causeskin irritation
Air Sampling in a Confined Room
Before BioCair® disinfection:TBC* 130cfu/m3 of airAfer disinfection:TBC <10cfu/m3 of air
FB819719/A
BioCair is proven to be fast & efective in killing airborne pathogens in the room

** Conclusions are based on tested subjects, duration and conditions.
* TBC = Total Bacteria Count
* cfu = colony forming unit

BioCair & Pathogens Chart

More Resistant

Pathogens

Less Resistant

More Resistant

Pathogens

Less Resistant

BioCair BC-65 is efective in achieving: > 5 log reduction for tested pathogens> 4 log reduction for Bacillus subtilis

BioCair Testings & Certifications

BioCair provides assurance of safety and efficacy through rigorous testing performed by highly-accredited laboratories, such as SGS, TUV and SETSCO. All products are manufactured to meet the highest ISO conditions with stringency in their tests, so that consumers can be sure they’re using a non-toxic disinfectant without worrying about adverse effects.

Efficacy Testing

Germ
Testing Laboratories
Country
Findings
Enterococcus hirae
Microbiological Solutions Limited
United Kingdom
99.999% Effective against E.hirae
Staphylococcus aureus (S.aureus)
99.999% Effective against S.aureus
Feline Coronavirus (FCoV)
99.999% Effective against FCoV
Vaccinia virus Ankara (MVA)
99.999% Effective against MVA
Clostridium difficile (C.difficile)
Melbec Microbiology
United Kingdom
99.999% Effective against C.difficile
Bacillus cereus (B.cereus)
99.999% Effective against B.cereus
Bacillus subtilis (B.subtilis)
SGS & Melbec Microbiology
Singapore & United Kingdom
99.999% Effective against B.subtilis
Escherichia coli (E.coli)
SGS & Microbiological Solutions Limited
Singapore & United Kingdom
99.999% Effective against E.coli
Pseudomonas aeruginosa (P.aeruginosa)
99.999% Effective against P.aeruginosa
SARS-CoV-2
CSIR BioScience
South Africa
Effective against SARS-CoV-2
HFMD virus (Coxsackievirus A16 & Enterovirus 71)
Singapore Polytechnic
Singapore
99.999% Effective against HFMD viruses
Aspergillus brasiliensis (A.brasiliensis)
SGS
Singapore
99.999% Effective against A.brasiliensis
Candida Albicans (C.albicans)
SGS
Singapore
99.999% Effective against C.albicans

Safety Testing

Study Item
Testing Laboratories
Findings
Conclusion
Lead Mercury Arsenic Analysis
TUV
Less than 0.05ppm
No lead, mercury and arsenic found, BioCair is safe for use
Acute Oral Route Toxicity Analysis
TUV
Category 5 or unclassified
BioCair does not cause ingestion toxicity
Acute Inhalation Toxicity Analysis
TUV
No acute inhalation toxicity was observed
BioCair does not cause inhalation toxicity
Ocular Irritation Analysis
TUV
No eye irritation after instillation
BioCair does not cause eye irritation
Acute Dermal Irritation Analysis
TUV
No skin irritation after instillation
BioCair does not cause skin irritation

Efficacy in Aerial Testing

Study Item
Testing Laboratories
Findings
Air Sampling in a confined room
SETSCO
Before BioCair disinfection: *TBC 130cfu/m3 of air After BioCair disinfection: *TBC < 10cfu/m3 of air
Aerial Testing via DeSage Active Air Sampling
Melbec Microbiology
90.3% reduction of CFU

*TBC = Total Bacteria Count, cfu = colony forming unit